1. Cáp Sấy MIQ Thermon Dây Gia Nhiệt Dùng Cho Dầu Khí
MIQ™ MINERAL INSULATED CABLE MIQ Thermon Dây Gia Nhiệt Dùng Cho Dầu Khí Cáp Sấy MIQ Thermon MIQ™ MINERAL INSULATED CABLE MIQ Thermon Dây Gia Nhiệt Dùng Cho Dầu Khí MIQ™ MINERAL INSULATED CABLE MIQ Thermon Dây Gia Nhiệt Dùng Cho Dầu Khí

Cáp Sấy MIQ Thermon Dây Gia Nhiệt Dùng Cho Dầu Khí

Series Constant Watt Heating Cable

MIQ high performance mineral insulated heating cables are used extensively for high temperature maintenance, high temperature exposure and/or high watt density applications which exceed the limitations of thermoplastic insulated cables. The resistance configurations available can provide tracing for pipes up to 1.6 km (1 mile) long from a single power supply point. Thermon’s MIQ mineral insulated cables are manufactured using Alloy 825, a high nickel/chromium alloy ideally suited for high temperature service that offers exceptional resistance to stress corrosion in chloride, acid, salt and alkaline environments. APPLICATION MIQ high performance mineral insulated heating cables are used extensively for high temperature maintenance, high temperature exposure and/or high watt density applications which exceed the limitations of thermoplastic insulated cables. The resistance configurations available can provide tracing for pipes up to 1 mile (1.6 km) long from a single power supply point. Thermon’s MIQ mineral insulated cables are manufactured using Alloy 825, a high nickel/chromium alloy ideally suited for high temperature service that offers exceptional resistance to stress corrosion in chloride, acid, salt and alkaline environments. MIQ cables are approved for use in ordinary (nonclassified) areas and hazardous (classified) areas. RATINGS Rated voltage 1 ......................................300 and 600 Vac Max. maintenance temperature 2 ..............932°F (500°C) Max. continuous exposure temperature Power-off............................................1,112°F (600°C) Max. watt density 2....................... up to 80 w/ft (262 w/m) Minimum installation temperature............... -76°F (-60°C) Minimum bend radius ................................ 6 x cable O.D. PRODUCT SPECIFICATIONS MIQ™ MINERAL INSULATED CABLE 1 2 3 D Pigtail Cold Lead Two Conductor Heated Length Hot-End Termination Used With 300 or 600 Vac, Two Conductor Cable B Pigtail Cold Lead One Conductor Heated Length Used With 600 Vac, One Conductor Cable Heater Set Types E Pigtail Cold Lead Two Conductor Heated Length Pigtail Cold Lead Used With 300 or 600 Vac, Two Conductor Cable A Pigtail Cold Lead One Conductor Heated Length Used With 600 Vac, One Conductor Cable D / MIQ-50E3H-2S / 200 / 1404 / 120 / 4 / 12 / 6 / 1 Design (A,B,D,E) Cable Reference Length (metric lengths followed by "M") Watts Volts Cold Lead Length (metric lengths followed by "M") Cold Lead size (AWG) Cold Lead Voltage Rating Hazardous (Classified) Location Rating 4 MIQ CATALOG REFERENCE NUMBER A complete catalogue reference number includes the following components: THERMON The Heat Tracing Specialists® Corporate Headquarters:100 Thermon Dr • PO Box 609 San Marcos, TX 78667-0609 • Phone: 512-396-5801 • 1-800-820-4328 For the Thermon office nearest you visit us at . . . www.thermon.com Form TEP0020-0714 • © Thermon Manufacturing Co. • Printed in U.S.A. • Information subject to change. Notes 1. Definition as stated in IEEE Standard 515. Specific voltage depends on circuit length and design conditions. 2. Watt density limitations are correlated to maintain temperatures. 3. Contact Thermon for gland size information. 4. If the field is blank, then the heating cable set is intended for ordinary (nonclassified) locations or Division 2 locations, or for use with AEx de, or Ex e enclosures. If the value in the field is “1”, then the heating cable set is intended for Division 1 locations, or for use with AEx d, or Ex d enclosures. CONSTRUCTION 1 Solid alloy or copper conductor(s) 2 Compacted magnesium oxide insulation 3 Seamless alloy 825 sheath MIQ HEATER SETS Thermon MIQ cable sets are available in four factory fabricated configurations: Type A, B, D or E. The standard assemblies consist of a predetermined length of heating cable joined to a standard 4’ (1.2 m) or 7’ (2.1 m) nonheating cold lead with 12” (305 mm) long thermoplastic insulated pigtails. The nonheating section of the unit is sealed and fitted with a high pressure, liquid-tight 1/2” or 3/4” NPT stainless steel gland 3 for connection into the supply junction box. CIRCUIT BREAKER SIZING 2 Maximum circuit lengths for various circuit breaker amperages are shown. Breaker sizing should be based on the National Electrical Code, Canadian Electrical Code or any other applicable code. The National Electrical Code and Canadian Electrical Code require ground-fault protection of equipment for each branch circuit supplying electric heating equipment. Che

MIQ™ MINERAL INSULATED MIQ Thermon Dây Gia Nhiệt Dùng Cho Dầu Khí

ĐT: 0356.975.994

Mailjan.tran@wili.com.vn

Để lại một bình luận

Email của bạn sẽ không được hiển thị công khai. Các trường bắt buộc được đánh dấu *