These top of the line heating cables provide both freeze protection and process temperature maintenance for metallic piping as well as non-metallic piping, tanks and equipment. The heat output of the cable is designed to change in response to the conditions along the entire circuit. When the heat loss of the equipment increases, the heat output of the cable increases. When the heat output decreases as ambient temperature rises, the cable output will decrease as well.The BSX™ is certified for use in ordinary areas and in potentially explosive atmospheres. The cable is easy to maintain and does not require steam cleaning.APPLICATIONBSX self-regulating heating cables are designed toprovide freeze protection or process temperaturemaintenance to metallic and nonmetallic piping,tanks and equipment. The heat output of BSX cablevaries in response to the surrounding conditionsalong the entire length of a circuit. Whenever theheat loss of the insulated pipe, tank or equipmentincreases (as ambient temperature drops), the heatoutput of the cable increases. Conversely, when theheat loss decreases (as the ambient temperaturerises or product flows), the cable reacts by reducingits heat output. BSX cables are approved for usein ordinary (nonclassified) areas and hazardous(classified) areas.RATINGSAvailable watt densities ...........10, 16, 26, 33 W/m @ 10°C(3, 5, 8, 10 W/ft @ 50°F)Supply voltages ...................................110-120 or 208-277 VacMax. maintenance temperature..................... 65°C (150°F)Max. continuous exposure temperaturePower-off....................................................................85°C (185°F)Minimum installation temperature ............ -51°C (-60°F)Minimum bend radius@ -15°C (5°F)........................................................10 mm (0.38”)@ -60°C (-76°F)................................................... 32 mm (1.25”)T-rating 110, 16, 26 W/m (3, 5, 8 W/ft).......................T6 85°C (185°F)33 W/m (10 W/ft)...........................................T5 100°C (212°F)Dây Gia Nhiệt Thermon BSX 10-2 OJ: Một giải pháp hiệu quả cho việc duy trì nhiệt độ
CONSTRUCTION1 Nickel-plated copper bus wires (16 AWG)2 Radiation cross-linked semiconductive heatingmatrix3 Radiation cross-linked dielectric insulation4 Tinned copper braid5 Polyolefin overjacket provides additionalprotection for cable and braid where exposure toaqueous inorganic chemicals is expected.OPTIONS6 FOJ Fluoropolymer overjacket over tinned copperbraid provides additional protection to cable andbraid where exposure to organic chemicals orcorrosives is expected.BASIC ACCESSORIESThermon offers system accessories designedspecifically for rapid, trouble-free installation ofThermon heating cables.All cables require a connection kit to comply withapproval requirements. Information on accessoriesto complete a heater circuit installation can be foundin the “Heating Cable Systems Accessories” productspecification sheet (Form TEP0010).