Dây Gia Nhiệt Thermon BSX 3-1 OJ

Dây Gia Nhiệt Thermon BSX 3-1 OJ

Day gia nhiet thermon BSX 10 2 oj scaled Day gia Nhiet Therrmon BSC 10 2 OJ 1 scaled

day gia nhiet thermon htsx, ksx, bsx, rsx

Self-Regulating Heating Cable

These top of the line heating cables provide both freeze protection and process temperature maintenance for metallic piping as well as non-metallic piping, tanks and equipment. The heat output of the cable is designed to change in response to the conditions along the entire circuit. When the heat loss of the equipment increases, the heat output of the cable increases. When the heat output decreases as ambient temperature rises, the cable output will decrease as well. The BSX™ is certified for use in ordinary areas and in potentially explosive atmospheres. The cable is easy to maintain and does not require steam cleaning.APPLICATION BSX self-regulating heating cables are designed to provide freeze protection or process temperature maintenance to metallic and nonmetallic piping, tanks and equipment. The heat output of BSX cable varies in response to the surrounding conditions along the entire length of a circuit. Whenever the heat loss of the insulated pipe, tank or equipment increases (as ambient temperature drops), the heat output of the cable increases. Conversely, when the heat loss decreases (as the ambient temperature rises or product flows), the cable reacts by reducing its heat output. BSX cables are approved for use in ordinary (nonclassified) areas and hazardous (classified) areas. RATINGS Available watt densities ...........10, 16, 26, 33 W/m @ 10°C (3, 5, 8, 10 W/ft @ 50°F) Supply voltages ...................................110-120 or 208-277 Vac Max. maintenance temperature..................... 65°C (150°F) Max. continuous exposure temperature Power-off....................................................................85°C (185°F) Minimum installation temperature ............ -51°C (-60°F) Minimum bend radius @ -15°C (5°F)........................................................10 mm (0.38”) @ -60°C (-76°F)................................................... 32 mm (1.25”) T-rating 1 10, 16, 26 W/m (3, 5, 8 W/ft).......................T6 85°C (185°F) 33 W/m (10 W/ft)...........................................T5 100°C (212°F)
BSX 10-2 OJ Dây Gia Nhiệt Thermon BSX 10-2 OJ: Một giải pháp hiệu quả cho việc duy trì nhiệt độ
Dây Gia Nhiệt Thermon BSX 10-2 OJ: Một giải pháp hiệu quả cho việc duy trì nhiệt độ
CONSTRUCTION 1 Nickel-plated copper bus wires (16 AWG) 2 Radiation cross-linked semiconductive heating matrix 3 Radiation cross-linked dielectric insulation 4 Tinned copper braid 5 Polyolefin overjacket provides additional protection for cable and braid where exposure to aqueous inorganic chemicals is expected. OPTIONS 6 FOJ Fluoropolymer overjacket over tinned copper braid provides additional protection to cable and braid where exposure to organic chemicals or corrosives is expected. BASIC ACCESSORIES Thermon offers system accessories designed specifically for rapid, trouble-free installation of Thermon heating cables. All cables require a connection kit to comply with approval requirements. Information on accessories to complete a heater circuit installation can be found in the “Heating Cable Systems Accessories” product specification sheet (Form TEP0010).

day gia nhiet thermon htsx, ksx, bsx, rsx

Dây Gia Nhiệt Thermon BSX 3-1 OJ

ĐT: 0356.975.994